The options this terminal has are the following:
- Whitelist Alarm / VIP List: Users can be grouped in one of these two lists, these boxes allow us to specify if the relay will act when the recognized user is in either of them
- IO Output:
- Continuous Output: The activation of the relay is for a determined time
- Press Output: The activation of the relay is by pulse
- Alarm Output: Time the relay will remain open
- Type: Configuration of the relay output type, whether normally open or closed
- Comparison Similarity: When the terminal recognizes a face and compares it with its DDBB, it indicates a degree of similarity. In this section we can specify what degree this comparison must have in order for the record to be correct. In the tests carried out, the degree does not usually go below 85%.
- Matching Mode: Allows us to specify which option we want to use as recognition, only temperature, Face +Temperature, etc, this allows us for example to use the terminal only to measure the temperature, without the need to recognize users. The options available are the following:
- Mask Detect: Obligation to wear a mask or not
- Temperature Correction: Compensation or correction of the temperature if we see that the terminal always detects a temperature of up to 1º of difference with reality
- Abnormal temperature opens the door
- Close: Default setting, the relay acts when the configured identification method is correct. For example, if we have configured the equipment with the option Temperature Detect, the relay will act when the temperature is correct
- Open: The relay will operate when the recognized temperature is incorrect
- Temperature threshold: Setting the temperature alarm value
- Temperature Unit: Unit of the temperature (Celsius or Fahrenheit)
- Time 1 / Time 2: Times when the terminal will open the relay, outside these times it will not be activated