IMPORTANT: Anviz advises against updating firmwares, as well as publishing them, since not all of them are suitable for all the units of a given reference. For this reason this article is for internal use only and its visibility is limited to agents and administrators.
This update process applies to Anviz C2PRO and C2PRO-MIFARE devices.
First of all, a USB flash drive in FAT32 format is required to perform the firmware update.
For this USB the file OA1100.zip must be inserted.
Important recommendations:
- do not decompress the file
- The USB to be used must not have any other files inside
With the device turned on, insert the USB into the port on the left side of the housing, as shown in the picture below:
The next step is to access the administrator menu. To do this, press the Me key to
enter the administrator user and password. Finally, click on the OK key to access
.
Credentials by default:
- User: 0
- Password: 12345
(If you have already saved fingerprint users with administrator permissions, you can also gain access with that method).
From the administrator menu you must navigate to the OPTION menu and access the new
submenu where you must navigate to UPDATE.
.
In the UPDATE menu, just click directly on OK.
Then, a notification will appear asking the user the authorization to update
the firmware by clicking on YES (OK).
An update bar will appear during the restart. When the update bar is completed, the device will be
switched on with the updated firmware: