This document provides the information necessary to configure the IMAX-B6-MINICHARGER charger to charge the Ajax AJ-INTERNALBATTERY-RB-64V36AH internal battery.
Important considerations:
• The Hub BP does not recharge this battery. It must always be recharged externally using this charger.
• Due to transportation regulations, the battery is never shipped at 100%: it arrives with approximately 30–50% of its capacity. It must be fully charged before commissioning.
• Installation companies that need to recharge these batteries compatible with Hub BP must have a compatible charger. The number of chargers will depend on the volume of installations, the initial charge level, and the need to perform simultaneous charging.
• The complete cycle from 0% takes approximately 9 hours. Charging time depends on the initial level, the battery condition, and the charging conditions. The Safety Timer must be configured to 720 minutes (11 h) as a safety limit; this value does not represent the usual cycle duration.
Connection and charging diagram for AJ-INTERNALBATTERY-RB-64V36AH with IMAX-B6-MINICHARGER
Charger
• Connect the 12 V power supply to the charger using the alligator-clip cable included in the kit. Check the polarity.
• The original XT60U-M adapter is mechanically polarized to reduce the risk of reverse connection. Before connecting the battery, visually check the condition of the adapter and the indicated polarity. Do not use modified cables or adapters other than the one supplied.
Ajax battery
• The connector to the Hub is already included in the battery package.
• The charger adapter is included in the battery box.
Charger configuration
(Charger buttons: BATT/PROG/STOP || START/ENTER || DEC || INC.)
1. General system configuration
Once per charger
2. Create the battery charging profile
Once per charger
3. Charge using the saved profile
For each charge
Safety precautions
⚠ ALWAYS select LiFe, never LiPo. This error may have direct safety consequences for the cells.
⚠ Mandatory: do not leave the cycle unattended, do not charge in vans or unconditioned premises during hot weather, and always use a noncombustible surface
⚠ Permitted temperature range for charging: 0–45 °C.
⚠ Charge on a noncombustible surface and under supervision.
⚠ Storage: At 30–50% charge, in a cool, dry, and ventilated place, below 30 °C.