First download and install the IP Manager Tool: - IP Manager Tool_1.0.7.14_20230322.
After the IP camera is already been activated but still on the default IP address and this is not in the IP range of the network. The IP address needs to be set to the IP address within range of the network IP range. When this is not clear what IP address to use, there is always the option to use the DHCP option in the camera.
Set Username and Password
1. Open the IP Manager Tool and go to the menu option in the top right of the IP Manager Tool software
2. Click on Modify Username/Password
3. Set the username and password from the camera that needs to be changed
4. Click on OK
Set the camera on DHCP
1. Click on Refresh
2. Select the camera that need to be changed (it is possible to select more than one camera)
3. Navigate to the tab Batch set Net
4. Select Obtain automatically
5. And Click on Batch Set
Give the camera an IP address
1. Click on Refresh
2. Select the camera that need to be changed (it is possible to select more than one camera)
3. Navigate to the tab Batch set Net
4. Select Use the following
5. Set the IP address subnet and gateway. The Start and End IP, depending on the number of selected cameras
6. And Click on Batch Set